PROBLEMS OF ATOMIC SCIENCE AND TECHNOLOGY
Series: Nuclear and Reactor Constants

since 1971

Русский (РФ)

ISSN 2414-1038 (online)

Authors & Affiliations

Di Piazza I.1, Tarantino M.1, Agostini P.1, Gaggini P.2, Polazzi G.1, Forgione N.3, Martelli D.3
1Italian National Agency for New Technologies, Energy and Sustainable Economic Development, Brasimone, Italy
2Italian National Agency for New Technologies, Energy and Sustainable Economic Deve lopment, Bologna, Italy
2University of Pisa, Pisa, Italy

Abstract

NACIE-UP test loop with lead-bismuth eutectic has fuel pin bundle simulator to measure clad temperature and heat transfer coefficients in the sub-channels. Natural circulation of liquid metal is provided in the loop. A gas-lift system provides forced circulation in the loop. Test facility is equipped with induction flow meters, differential manometers, and thermocouples. The paper reports the description of the experiment, the proposed test matrix and description the technological solution adopted for the NACIE-UP implementation.

Keywords
lead-bismuth eutectic, NACIE-UP test loop, natural circulation, mixed convection, fuel pin bundle simulator, clad temperature, heat transfer coefficient

Article Text (PDF)

References

UDC 621.039.53

Problems of Atomic Science and Technology. Series: Nuclear and Reactor Constants,2015, issue 4, 4:4